Home / Blog
Radon Design Blog
Guides on radon-control design for multifamily, HUD, school, and commercial construction, keyed to the ANSI/AARST standards reviewers check for.
Published July 28, 2026
Radon Mitigation Design for New Schools
How to design a radon mitigation system for a new school to ANSI/AARST CC-1000-2018: which standard applies and how footprint drives system count.
Read the guidePublished July 24, 2026
Radon Control System Design for Commercial Buildings
A commercial radon control system design is a stamped plan that keeps soil gas out of a new building, fixing sub-slab layout, barrier, and vent stack.
Read the guidePublished July 21, 2026
Radon Vent Stack Sizing for Multifamily Buildings
How radon vent stack sizing works for multifamily buildings: the 2-inch, 3-inch, and 4-inch airflow bands, and what pressure field extension decides.
Read the guidePublished July 17, 2026
Passive vs. Active Radon Control in New Construction
Passive radon control vents soil gas on stack effect; active adds a fan. New construction starts passive, converting only if a test exceeds the limit.
Read the guidePublished July 14, 2026
What Is Included in a Radon Mitigation Design Package for Large Buildings
A large-building radon mitigation design package includes collection layout drawings, barrier and sealing specifications, vent routing, and fan provisions.
Read the guidePublished July 10, 2026
Radon System Design for New Apartment Buildings
How to design a radon system for a new apartment building to ANSI/AARST CC-1000-2018: package scope, passive vs. active control, and vent routing.
Read the guidePublished July 7, 2026
SGM-MFLB-2023 Radon Mitigation in Existing Large Buildings
ANSI/AARST SGM-MFLB-2023 is the standard for mitigating radon in existing multifamily, school, and commercial buildings, and what a design must contain.
Read the guidePublished July 3, 2026
HUD Radon Requirements for Multifamily Housing
HUD-financed multifamily housing addresses radon two ways: ANSI/AARST testing at a 4.0 pCi/L action level, and CC-1000-2018 design for new construction.
Read the guidePublished June 30, 2026
ANSI/AARST CC-1000 Radon Design Requirements for New Construction
ANSI/AARST CC-1000-2018 sets radon design requirements for new multifamily, school, and commercial construction: gas barrier and sub-slab collection.
Read the guidePublished June 29, 2026
Radon Mitigation Design for Multifamily Buildings
How to design a radon mitigation system for a multifamily building to ANSI/AARST CC-1000-2018: package scope, passive vs. active, and HUD requirements.
Read the guide
Scoping a radon design package?
Send your plans and we return a fixed quote for a stamped, code-keyed radon design before any work starts.
Request a quote